Vue de la page 81
HP
16515A/16A
-
Service
6-7. MODULE REPLACEMENT
The
effects of
ELECTROSTATIC
DISCHARGE
can
damage electronic com-
ponents.
Use
grounded wriststraps and
mats
when
performing any kind of ser-
vice
to
this module.
Installation Considerations:
A two card module must
remain
screwed together
and
installed
in
two adjacent
slots.
A
one
card module
may
be
installed
in
any
available
slot
If previously
installed
modules prevent proper installation, they must
be
repositioned
in
the card
cage.
Cards
or filler
panels
below
the
slot(s)
intended
for module installation do not
have
to
be
removed.
The
probe
assemblies
do not
have
to
be
removed
to install the module.
Procedure:
1.
Turn
instrument power switch
off,
disconnect power cord
and
any Input or output connections.
2. Starting from the top, loosen thumb
screws
on
filler
panel(s)
and
card(s).
4
Note
Two
card 1
GHz
Timing
Modules
are
screwed together.
To
prevent binding
when
loosening or tightening
thumbscrews,
use
sequence shown
in
figure
6-12.
1f$1I1~16A
lc:Hz
TlimlC
EXPANSION I
o
,--------,I
L-I
_--JI
1
. I
,-I
_---'
1~16515A
lc:Hz TIIoIINC
MASTER
I
o
1----111
L-
_--,I
,-I
_---'I
L-I
_--'
16515/EX3-4
Figure
6-12. Tightening Or Loosening Sequence
3
2
3.
Starting from the top,
begin
pulling
card(s)
and
filler
panel(s)
out half
way.
See
figure
6-13.
6-28