•Reversetheorderoftheaboveproceduretoreassemble.
•Checkforgasleaksandtheoperationoftheignition
system.
6. PIEZO
6.1 If a new piezo is required, it will be necessary to change the
gas valve. Refer to Section 7.
7. GAS VALVE
• RemovetheburnerunitasdescribedinSection2.
•Disconnectthethermocoupleandinterrupterblock
complete with leads. See diagram 10, Arrow A.
10
AR1571
D
C
E
A
B
D
C
•Disconnectthefeedpipetotheinjectorandthebrass
elbow from the gas valve noting the orientation. See
diagram 10, Arrow B.
•Disconnecttheinletpipealongwiththepilotpipe.See
diagram 10, Arrow C.
NOTE: When removing the inlet pipe do not remove the
brass fitting from the side of the gas valve.
•Disconnecttheignitionleadfromthegasvalve.See
Section 5.
• Undothetwoscrewssecuringthegasvalvetothe
control bracket and remove the valve. See diagram 10,
Arrow D.
• Replaceinreverseorder.Checkalljointsforgasleaks
and operation of ignition lead.
8. MAGNETIC SAFETY VALVE
• RemovetheburnerunitasdescribedinSection2.
• Removethethermocouplealongwiththeinterrupter
block and leads. See diagram 10, Arrow A.
•Undothemagunitretainingnut.Seediagram10,Arrow
E.
8.1 After removing the retaining nut, the mag unit can be
tapped out and a replacement fitted.
• Replacethemagunitretainingnutandtighten.
NOTE: This is a gas-tight seal
• Replacethethermocouple,interrupterblockandleads
and check for gas leaks.
8.2 After reassembly, carry out the flame failure functional
check, detailed in the flow chart, particularly the mag unit
drop out time.
9. COMBUSTION PRODUCTS DISCHARGE
SAFETY DEVICE
This sensor measures the temperature of the flue and is
located in the diverter on the flue outlet. This important
safety device prevents products of combustion entering a
room and must operate at all times when the cooker is in
use.
The flue sensor switches the burner off if the temperature is
too high and the cooker refuses to relight. You must wait 30
minutes before you can press the reset button in the control
panel to relight the cooker. When there is repeated
shutdown of the cooker the flue/chimney must be
investigated immediately:
9.1 The Reset button is behind the control panel door:
•Presstoreset.
9.2 After each shutdown by the flue sensor, an operation test of
the cooker and flue must be carried out. (See
Commissioning).
NOTE: BEFORE PROCEEDING, ISOLATE THE ELECTRIC
SUPPLY
9.3 To replace the device:
• Openthecontroldoorandremovethetwoscrews
retaining the front panel. See diagram 11, Arrow A.
11
AR1551
A
A
•RemovethetwowiresfromtheTTBbodyandundothe
retaining nut. See diagram 12.
SERVICING INSTRUCTIONS
REPLACING PARTS
26