Caple C981G Manuel d'instructions Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
11
INSTRUCTIONS FOR THE INSTALLER
MAINTENANCE
Replacing the power supply cable
Should it be necessary to replace the power supply
cable, use a standard type H05VV-F or H05RR-F cable
with a section of 3 x 0.75 mm
2
.
The connection to the terminal board must be carried
out as shown in the figure on the right:
Brown wire L (live)
Blue wire N (neutral)
Green-yellow wire (earth)
TECHNICAL SPECIFICATIONS TABLE
BURNERS
GAS
WORKING
PRESSURE
HEAT INPUT
NOZZLE
DIAMETER
REGULATORS BY-
PASS DIAMETER
HEAT INPUT
(W)
DESIGNATION
mbar g/h L/h 1/100 mm 1/100 mm Max. Min.
1 RAPID
G30 28-30 218 - 87 42 3000 950
G31 37 214 - 87 42 3000 950
G20 20 - 286 129 Reg. 3000 950
G25 25 - 332 132 Reg. 3000 950
2 SEMI-RAPID
G30 28-30 120 - 65 31 1650 600
G31 37 118 - 65 31 1650 600
G20 20 - 157 97 Reg. 1650 600
G25 25 - 183 100 Reg. 1650 600
3 AUXILIARY
G30 28-30 73 - 50 27 1000 450
G31 37 71 - 50 27 1000 450
G20 20 - 95 77 Reg. 1000 450
G25 25 - 111 80 Reg. 1000 450
4 TRIPLE CROWN
G30 28-30 255 - 46 / 65 60 4000 2100
G31 37 250 - 46 / 65 60 4000 2100
G20 20 - 334 71 / 95 Reg. 4000 2100
G25 25 - 443 71 / 100 Reg. 4000 2100
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 19 20

Commentaires sur ces manuels

Pas de commentaire