Caple CR 1200 Manuel d'instructions Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
Green & Yellow
(Earth)
Brown (Live)
Blue (Neutral)
N
L
Fig. 1.1
Fig. 1.2
WARNING: This appliance must be earthed
A
C
P
D
B
CONNECTING THE DOUBLE OVEN MAINS CABLE
IMPORTANT: This oven must be connected to the mains power supply only by a
suitably qualified person.
Unscrew the screw A securing the cover plate B behind the oven (fig. 1.1).
Remove the cover plate B.
Remove the screws C from the cable clamp (fig. 1.2).
Insert the mains cable (type H05RR-F or H05VV-F - 3x2,5 mm
2
section) into the
cable protector P.
Connect the phase and earth cables to the mains terminal connection block D.
EARTH
N NEUTRAL
L LIVE
Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw
the screws C.
Refit the cover plate B and fix it with the screw A.
If the supply cord is damaged, it must be replaced by a qualified technician
in order to avoid a hazard.
N
L
1 (L )2 E
7