Caple C804C Spécifications Page 136

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 150
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 135
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Appendix B Revision 8
B–6
Click [Change] to save these settings.
Set Switch Position (1:1 only)
In Manual Mode only To force a unit into the active online state, use the drop-down list to
select a unit number, and then click [Send the Command].
Gain Offset (1:1 only)
Enter the gain offset, in 0.25 dB steps, and then click [Change].
Force Back-up State (1:2 only)
Use the drop-down list to set the back-up state as follows:
Select Unit 01 or Unit 02 to put that HPOD into an offline state and set the Redundancy
Mode to Manual.
Select None to put the backup unit offline and set the Redundancy Mode to Automatic.
Click [Change] to save this setting.
Backup Offset for Unit 01 (1:2 only)
Enter the Backup Offset for Unit 01, in 0.25 dB steps, and then click [Change].
Backup Offset for Unit 02 (1:2 only)
Enter the Backup Offset for Unit 02, in 0.25 dB steps, and then click [Change].
Online Status
The active status for the unit is identified here as Online or Offline.
.
Vue de la page 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 149 150

Commentaires sur ces manuels

Pas de commentaire