HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier MN/HPOD.IOM
Appendix C Revision 8
C–6
C.4 Scheduled Maintenance
The SSPA heat sink should be cleaned once a year or sooner, depending on
environmental conditions.
To perform this maintenance, do these steps:
Step Task
1
Disconnect the HPOD SSPA from its power source.
2
Remove the power supply as instructed in
Sect. C.2.1
.
3
Remove the fan assembly as instructed in
Sect. C.3.1
.
4
Use compressed air to clear the heat sink portions of the power supply.
5
Use compressed air to blow through
the SSPA heat sink to remove any foreign object accumulation
that may be obstructing airflow.
6
Re-install the power supply as instructed in
Sect. C.2.2
.
7
Re-install the fan assembly as instructed in
Sect. C.3.2
.
8
Reconnect the HPOD SSPA to its power source.