Revision 1.9 - 33 -
3/8" or less
Easy Move slide sensor
Proximity switch plate
B
-
15 Lift arm sensor
6.10
Easy Move Sensor Adjustment and setup
The PALFINGER Liftgates ILFP Easy Move is a self-adjusting sliding option. The Easy Move requires
- (1) B-15 Sensor, mounted to the inside of the main lift arm
- (1) Proximity switch, installed at the sliding mount plate
- (1) Proximity switch plate, attached to the sliding rail
When successfully installed the ILFP, the Easy Move option has to be activated. In order to do that,
proceed with the following steps:
1) Slide the gate into its stored position and raise it up, make sure the proximity switch is being
overlapped by the metal sensor plate on the slide rail – distance approx. 3/8” or less.
2) Connect the J-41 Plug to the board to activate the B-15 Sensor
Proximity switch
Adjustable proximity