Caple C602E Manuel d'installation Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
Revision 1.9 - 34 -
Slide angle sensor
B-15 Lift arm
Voltage difference
between store and
slide position
0.34 V @ blue
1Meg Ohm Resistor
a. Attach your digital voltmeter to the blue (signal) and brown (ground) cables on the J-41 plug
b. Voltage should be between 1.4V and 1.6V with gate in stored position
i. If necessary rotate B-15 lift arm sensor within oblong hole to achieve voltage range
ii. After adjusting B-15 unplug and reattach J-1 plug for reset the signal to board
3) With sensor fine-tuned and gate activated, run gate through (2) full cycles.
a. Slide gate out and LOWER to floor. Activate “slide in” function. Gate will raise and lift at the
same time until preset slide level is reached. Gate will slide in and lift up into travel position
when reached end position.
b. Slide gate out and LIFT to truck bed. Activate “slide in” function. Gate will lower until preset
slide level is reached. Gate will slide in and lift up into travel position when reached end
position.
Oblong hole in B-15 sensor
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 40

Commentaires sur ces manuels

Pas de commentaire